A study led by IDIBAPS researchers has shown the usefulness of optical coherence tomography (OCT), a diagnostic imaging technique widely used in ophthalmology, for monitoring patients with multiple sclerosis (MS). The analysis of the retina with this technique can determine the risk of clinical worsening of those patients. Dr. Pablo Villoslada, head of the IDIBAPS Pathogenesis and new treatments in Multiple Sclerosis, and Dr. Elena H. Martinez-Lapiscina, researcher of the same group and head of the Visual Pathway Lab, coordinate this article published in The Lancet Neurology. Researchers from centers in Spain, Italy, France, Germany, Czech Republic, Holland, Canada and the United States have been involved in this study.

Multiple sclerosis (MS) is a disease that has an unpredictable course, so it is necessary an accurate patients’ follow-up to provide the best treatment. Development of imaging biomarkers for prediction of the clinical course of the disease would improve the management of patients. Most people with MS show inflammatory and neurodegenerative signs in the retina. Optical coherence tomography (OCT) is very reproducible and high-resolution imaging method for the assessment of retinal integrity.

In the study published in The Lancet Neurology, researchers included 879 patients with MS from 20 centers worldwide to assess whether the OCT is a useful technique to follow the course of the disease. This technique measured the thickness of the retina in patients over time, with a follow-up between 6 months and five years. They have established that below a certain retinal thickness, set at 88 microns, patients have a worse evolution of their illness. Thus, patients with retinal thickness below this value have twice the risk of disability worsening between the first and up to the third years of follow-up, and the risk increases uo to four times between 3 and 5 years of follow-up. The OCT is used to monitor disease progression and, because this technique less expensive and easier to perform than other used, as MRI, it can be useful for routine monitoring of patients. "The aim is not to replace the MRI, but OCT allows us to perform the test when the patient comes for consultation every 6 months", explains Dr. Elena H. Martinez-Lapiscina.

"Thanks to its high resolution, OCT can measure tiny changes that other techniques are impossible to identify. The idea is to incorporate this technique, used in ophthalmology, in the clinical practice in neurology. It could be also useful in diseases such as Alzheimer, Parkinson's disease or cerebral trauma", explains Dr. Pablo Villoslada. In addition, "our group is working on developing new technologies to monitor retinal and neurological diseases based on electrophysiology and molecular laser imaging, which would see the changes throughout the disease in an early stage" he concludes. For this purpose the IDIBAPS group collaborates with the Institute of Photonic Sciences (ICFO) and the Institute for Energy Research of Catalonia (IREC).

Subscribe to Directory
Write an Article

Recent News

El diagnóstico genético neonatal mejor...

Un estudio con datos de los últimos 35 años, ind...

Más de 1.500 cambios epigenéticos en e...

Un equipo de investigadores de la Universidad Juli...

Tuneable reverse photochromes in the sol...

A new technique allows the design of solid materia...

Highlight

Eosinófilos. ¿Qué significa tener val...

by Labo'Life

​En nuestro post hablamos sobre este interesante tipo de célula del...

Un estudio de INCLIVA muestra el efecto ...

by INCLIVA

Han desarrollado un estudio para evaluar la correlación entre el teji...

Photos Stream